Support Center > Knowledgebase> Article: The vacuum tube on the APR-5000-XL is stuck and/or binding when in FREE mode?

The vacuum tube on the APR-5000-XL is stuck and/or binding when in FREE mode?

Article ID: 97246 Email Print
Question
The vacuum tube on the APR-5000-XL is stuck and/or binding when in FREE mode?

Answer

Possible Causes:

1) Flux build up in vacuum tube bushing and/or collet.

2) No vacuum to the bottom inlet on air cylinder.

3) Bad air cylinder.

4) Vacuum tube is bent.

Solutions (corresponding to the Causes #):

1) Remove the vacuum tube and carefilly clean vacuum tube bushings with alcohol or acetone. Clean the collet.

2) Check for vacuum at the hose with the green stripe. Check that it is not kinked. Also, check vacuum pump operation (APR-VPC). Check/replacement instructions: APR-VPC - Tube.pdf

3) Replace air cylinder (APR-PAC). Replacement instructions: XL APR-PAC Replace.pdf.

4) Replace the vacuum tube (APR-XLVPUK). Replacement instructions: APR-XL Replace Vac Tube.pdf

If you need instructions on how to replace or check any of these parts, please contact our APR Support Team.