Support Center > Knowledgebase> Article: Is there no or low vacuum pickup on the APR-5000-XL?

Is there no or low vacuum pickup on the APR-5000-XL?

Article ID: 97250 Email Print
Question
Is there no or low vacuum pickup on the APR-5000-XL?

Answer

Possible Causes:

1) Bad vacuum pump.

2) Clogged vacuum filter.

3) Clogged vacuum tube or elbow fitting.

Possible Solutions (corresponding to the Causes #):

1) Check for vacuum pump activation (sound). Replace vacuum pump (APR-VPC). Replacement instructions: APR-VPC - Airflow.pdf

2) Replace filter (APR-VF). Reflow Head Inner Locations.pdf

3) Remove and clean vacuum tube and elbow fitting.

If you need instructions on how to replace or check any of these parts, please contact our APR Support Team.


related articles

Article Details
Views: 419 Created on: Aug 31, 2018
Date updated: Sep 04, 2018
Tagged: Vacuum, pump