Support Center > Knowledgebase> Article: Is there no heat from the Reflow (Top) Heater on the APR-5000-XL?

Is there no heat from the Reflow (Top) Heater on the APR-5000-XL?

Article ID: 97306 Email Print
Question
Is there no heat from the Reflow (Top) Heater on the APR-5000-XL?

Answer

Possible Causes:

1) The Reflow Heater is bad.

2) The RTD in the Reflow Heater is bad.

3) Bad solid state relay on the main PCBA.

Possible Solution (corresponding to the Causes #):

1) Check the heater resistance. Replace heater head assembly (APR-HHA). Replacement instructions: APR-HHA Replace.pdf

2) Check RTD resistance. Replace heater head assembly (APR-HHA). replacement instructions: APR-HHA Replace.pdf

3) Replace the main PCBA (APR-XL-LCPCB). Replacement instructions: APR-XL-LCPCB Replacement Instructions.pdf

If you need instructions on how to replace or check any of these parts, please contact our APR Support Team.


related articles

Article Details
Views: 314 Created on: Sep 04, 2018
Date updated: Sep 04, 2018