The vacuum tube on the APR-5000-XL does not go to UP or FREE modes?
|
|
|
Possible Causes: 1) Broken or leaking tube connection to air cylinder. 2) Bad vacuum pump. 3) Bad air cylinder. Possible Solutions (corresponding to the Causes #): 1) Check tubing from vacuum pump in the chassis to air cylinder in the head. 2) Replace vacuum pump (APR-VPC). Replacement instru...
|
|
Reflow head is squeaking or binding when moving in the Z-Axis? |
|
|
The Z-Axis leadscrew likely needs lubrication. Lubrication instructions: APR-XL Z-AXIS Lubrication.pdf....
|
|
The vacuum tube on the APR-5000-XL is stuck and/or binding when in FREE mode?
|
|
|
Possible Causes: 1) Flux build up in vacuum tube bushing and/or collet. 2) No vacuum to the bottom inlet on air cylinder. 3) Bad air cylinder. 4) Vacuum tube is bent. Solutions (corresponding to the Causes #): 1) Remove the vacuum tube and carefilly clean vacuum tube bushings with alcohol or ...
|
|
Reflow head on the APR-5000-XL does not move up or down? |
|
|
Possible Causes: 1) Bad connection to Z-Axis motor. 2) Bad connection to action button board to main control PCBA. 3) Bad Z-motor assembly. 4) Bad flag sensor. 5) Loose wiring to Lynx motor controller #1. 6) Bad Lynx motor controller #1. 7) Bad action button board (buttons or board traces). ...
|
|
No X-Axis movement on the APR-5000-XL?
|
|
|
Possible Causes: 1) Bad connection somewher in the machine. 2) Bad joy stick assembly. 3) Loose wiring to Lynx motor controller #4 4) Bad Lynx motor controller #4. 5) Bad enable button assembly. 6)Bad X-Axis motor assembly. Possible Solutions (corresponding to the Causes #): 1) Check all co...
|
|
No Y-Axis movement on the APR-5000-XL? |
|
|
Possible Causes: 1) Bad connection somewher in the machine. 2) Bad joy stick assembly. 3) Loose wiring to Lynx motor controller #3. 4) Bad Lynx motor controller #3. 5) Bad enable button assembly. 6)Bad X-Axis motor assembly. Possible Solutions (corresponding to the Causes #): 1) Check all c...
|
|
No theta (rotational) movement on the APR-5000-XL?
|
|
|
Possible Causes: 1) Bad connections within the machine. 2) Stripped gear. 3) Bad enable button assembly. 4) Bad joystick. 5) Bad motor. 6) Loose wiring Lynx motor controller #2. 7) Bad Lynx motor controller #2. Possible Solutions (corresponding to the Causes #): 1) Check all wire harness c...
|
|
The Enter (Next) button does not work on the APR-5000-XL? |
|
|
Possible Causes: 1) Bad connections. 2) Bad action button PCB. Possible Solutions (corresponding to the Causes #): 1) Check the connection from the action button PCB to the control PCB 2) Replace the action button PCB (APR-XLABK). Replacement instructions: Replace APR-XLABK Action Board.pdf I...
|
|
Is there no or low vacuum pickup on the APR-5000-XL?
|
|
|
Possible Causes: 1) Bad vacuum pump. 2) Clogged vacuum filter. 3) Clogged vacuum tube or elbow fitting. Possible Solutions (corresponding to the Causes #): 1) Check for vacuum pump activation (sound). Replace vacuum pump (APR-VPC). Replacement instructions: APR-VPC - Airflow.pdf 2) Replace fi...
|
|
Is there an Overtemp Hardware Error (13) or (15) on the APR-5000-XL? |
|
|
Possible Causes: 1) Review profile plot. If ramp rate to overtemp does not look realistic (there is a vertical upshoot) then possible bad RTD or bad RTD connection. 2) There is a software lockup. 3) Review profile plot. If ramp rate to overtemp looks realistic, then it may be bad top heater cont...
|
|
Is there no airflow or reduced airflow at the Reflow Head on the APR-5000-XL?
|
|
|
Possible Causes: 1) Kinked air hose or hose not connected. 2) Incorrect setting in the software. 3) Bad connection. 4) No control voltage. 5) Bad reflow pump. Possible Solutions (corresponding to the Causes #): 1) Check the white-striped hose connected to the lower inlet on the reflow heater...
|
|
What power input does the APR-5000-XL use? |
|
|
The APR-5000-XL uses 200-240VAC, 50/60Hz, 20 Amp, Single Phase....
|
|
How often does the APR-5000-XL need to be calibrated?
|
|
|
It is recommended that the APR-5000-XL is calibrated every 12 months or as required. More calibration information can be found on the website....
|
|
What is the field of view on the camera for the Scorpion Rework System? |
|
|
The maximum field of view is 60mm x 45mm (2.36" x 1.77") and the minimum viewable component size is 0.51mm x 0.25mm (0.020" x 0.010" )....
|
|
What is the power consumption of the APR-5000-XL?
|
|
|
System Total: 3700W Large Pre-Heater: 2800W Small Pre-heater: 1400W Reflow Heater: 550W...
|