Orange arrow How often does the APR-5000-XL need to be calibrated?

609 views
  It is recommended that the APR-5000-XL is calibrated every 12 months or as required. More calibration information can be found on the website....
Orange arrow What is the power consumption of the APR-5000-XL?

787 views
  System Total: 3700W Large Pre-Heater: 2800W Small Pre-heater: 1400W Reflow Heater: 550W...
Orange arrow How often does the Scorpion Rework System need to be calibrated?

661 views
  External Thermocouple Calibration: Every 12 months or as required Heater Calibrations: Every 12 months or as required Optical Calibration: Every 6-12 months or as required...
Orange arrow How do I calibrate my Scorpion Rework System?

418 views
  For optical calibration, each Scorpion comes with an optical calibration kit. For thermal calibration, you can purchase or rent a thermal calibration kit to perform the calibration yourself, or you can schedule an on-site calibration service. All caibration information can be found here....
Orange arrow What are the maximum temperature settings of each heater on the Scorpion Rework System?

431 views
  Reflow heater: 400°C (752ºF) Inner Preheater: 350ºC (662ºF) Outer Preheater: 350ºC (662ºF)...
Orange arrow What are the heater ratings for the Scorpion Rework System?

454 views
  Small (Inner) Preheater: 900W Large (Outer) Preheater: 1800W Reflow (Top) Heater: 550W...
Orange arrow What type of heating technology is used in the Scorpion Rework Systems?

532 views
  The Scorpion Rework Systems use convection heating technology....
Orange arrow Is there no heat from the Reflow (Top) Heater on the APR-5000-XL?

338 views
  Possible Causes: 1) The Reflow Heater is bad. 2) The RTD in the Reflow Heater is bad. 3) Bad solid state relay on the main PCBA. Possible Solution (corresponding to the Causes #): 1) Check the heater resistance. Replace heater head assembly (APR-HHA). Replacement instructions: APR-HHA Replace....
Orange arrow Is there an odd or strange plot for the Reflow Heater RTD on the APR-5000-XL?

322 views
  Possible Causes: 1) The RTD is out of possition. 2) There is a bad or intermittent RTD connection. Possible Solutions (corresponding to the Causes #): 1) Remove the heater head cover and reposition the RTD. APR-HHA Main RTD Position.pdf 2) Tighten the female connectors to the heater head RTD h...
Tagged: heating, heat, Heater, rtd, plot


Orange arrow Is there an Overtemp Hardware Error (13) or (15) on the APR-5000-XL?

366 views
  Possible Causes: 1) Review profile plot. If ramp rate to overtemp does not look realistic (there is a vertical upshoot) then possible bad RTD or bad RTD connection. 2) There is a software lockup. 3) Review profile plot. If ramp rate to overtemp looks realistic, then it may be bad top heater cont...
Tagged: plot, overtemp, 13


Orange arrow Is there no or low Pre-Heater (bottom) heat on the APR-5000-XL?

558 views
  Possible Causes: 1) There is a bad connection. 2) Incorrect off-set setting in software. 3) No or low airflow through Pre-Heater. 4) Bad heater. 5) Bad solid state relay. Possible Solutions (corresponding to the Causes #): 1) Check connections to all heaters, both solid state relays, and the...
Orange arrow Is there a Pre-Heater RTD error on the APR-5000-XL?

539 views
  Possible Causes: 1) Bad connections or not plugged in. 2) Bad RTD. Possible Solutions (corresponding to the Causes #): 1) Check all connections to RTD's and to the PCB. 2) Replace the RTD assembly. Replacement instructions: APR-XL Preheater and RTD replacement.pdf If you need instructions on ...