Orange arrow Reflow head on the APR-5000-XL does not move up or down?

479 views
  Possible Causes: 1) Bad connection to Z-Axis motor. 2) Bad connection to action button board to main control PCBA. 3) Bad Z-motor assembly. 4) Bad flag sensor. 5) Loose wiring to Lynx motor controller #1. 6) Bad Lynx motor controller #1. 7) Bad action button board (buttons or board traces). ...
Tagged: up, z-axis, down, lynx


Orange arrow No X-Axis movement on the APR-5000-XL?

487 views
  Possible Causes: 1) Bad connection somewher in the machine. 2) Bad joy stick assembly. 3) Loose wiring to Lynx motor controller #4 4) Bad Lynx motor controller #4. 5) Bad enable button assembly. 6)Bad X-Axis motor assembly. Possible Solutions (corresponding to the Causes #): 1) Check all co...
Tagged: lynx, motor, joystick


Orange arrow No Y-Axis movement on the APR-5000-XL?

334 views
  Possible Causes: 1) Bad connection somewher in the machine. 2) Bad joy stick assembly. 3) Loose wiring to Lynx motor controller #3. 4) Bad Lynx motor controller #3. 5) Bad enable button assembly. 6)Bad X-Axis motor assembly. Possible Solutions (corresponding to the Causes #): 1) Check all c...
Tagged: lynx, motor, joystick


Orange arrow No theta (rotational) movement on the APR-5000-XL?

373 views
  Possible Causes: 1) Bad connections within the machine. 2) Stripped gear. 3) Bad enable button assembly. 4) Bad joystick. 5) Bad motor. 6) Loose wiring Lynx motor controller #2. 7) Bad Lynx motor controller #2. Possible Solutions (corresponding to the Causes #): 1) Check all wire harness c...