Is there no heat from the Reflow (Top) Heater on the APR-5000-XL?
|
|
|
Possible Causes: 1) The Reflow Heater is bad. 2) The RTD in the Reflow Heater is bad. 3) Bad solid state relay on the main PCBA. Possible Solution (corresponding to the Causes #): 1) Check the heater resistance. Replace heater head assembly (APR-HHA). Replacement instructions: APR-HHA Replace....
|
|
Is there an odd or strange plot for the Reflow Heater RTD on the APR-5000-XL? |
|
|
Possible Causes: 1) The RTD is out of possition. 2) There is a bad or intermittent RTD connection. Possible Solutions (corresponding to the Causes #): 1) Remove the heater head cover and reposition the RTD. APR-HHA Main RTD Position.pdf 2) Tighten the female connectors to the heater head RTD h...
|
|
Is there a Pre-Heater RTD error on the APR-5000-XL?
|
|
|