Support Center > Knowledgebase> Tagged: preheater
Tag: preheater
5 Articles
Orange arrow What are the heater ratings for the Scorpion Rework System?

454 views
  Small (Inner) Preheater: 900W Large (Outer) Preheater: 1800W Reflow (Top) Heater: 550W...
Orange arrow How do I calibrate my Scorpion Rework System?

418 views
  For optical calibration, each Scorpion comes with an optical calibration kit. For thermal calibration, you can purchase or rent a thermal calibration kit to perform the calibration yourself, or you can schedule an on-site calibration service. All caibration information can be found here....
Orange arrow How often does the APR-5000-XL need to be calibrated?

609 views
  It is recommended that the APR-5000-XL is calibrated every 12 months or as required. More calibration information can be found on the website....
Orange arrow Is there no or low Pre-Heater (bottom) heat on the APR-5000-XL?

558 views
  Possible Causes: 1) There is a bad connection. 2) Incorrect off-set setting in software. 3) No or low airflow through Pre-Heater. 4) Bad heater. 5) Bad solid state relay. Possible Solutions (corresponding to the Causes #): 1) Check connections to all heaters, both solid state relays, and the...
Orange arrow Is there a Pre-Heater RTD error on the APR-5000-XL?

539 views
  Possible Causes: 1) Bad connections or not plugged in. 2) Bad RTD. Possible Solutions (corresponding to the Causes #): 1) Check all connections to RTD's and to the PCB. 2) Replace the RTD assembly. Replacement instructions: APR-XL Preheater and RTD replacement.pdf If you need instructions on ...