What are the heater ratings for the Scorpion Rework System?
|
|
|
Small (Inner) Preheater: 900W Large (Outer) Preheater: 1800W Reflow (Top) Heater: 550W...
|
|
How do I calibrate my Scorpion Rework System? |
|
|
For optical calibration, each Scorpion comes with an optical calibration kit. For thermal calibration, you can purchase or rent a thermal calibration kit to perform the calibration yourself, or you can schedule an on-site calibration service. All caibration information can be found here....
|
|
How often does the APR-5000-XL need to be calibrated?
|
|
|
It is recommended that the APR-5000-XL is calibrated every 12 months or as required. More calibration information can be found on the website....
|
|
Is there no or low Pre-Heater (bottom) heat on the APR-5000-XL? |
|
|
Possible Causes: 1) There is a bad connection. 2) Incorrect off-set setting in software. 3) No or low airflow through Pre-Heater. 4) Bad heater. 5) Bad solid state relay. Possible Solutions (corresponding to the Causes #): 1) Check connections to all heaters, both solid state relays, and the...
|
|
Is there a Pre-Heater RTD error on the APR-5000-XL?
|
|
|
Possible Causes: 1) Bad connections or not plugged in. 2) Bad RTD. Possible Solutions (corresponding to the Causes #): 1) Check all connections to RTD's and to the PCB. 2) Replace the RTD assembly. Replacement instructions: APR-XL Preheater and RTD replacement.pdf If you need instructions on ...
|