Support Center > Knowledgebase> Tagged: Heater
Tag: Heater
6 Articles
Orange arrow How often does the Scorpion Rework System need to be calibrated?

788 views
  External Thermocouple Calibration: Every 12 months or as required Heater Calibrations: Every 12 months or as required Optical Calibration: Every 6-12 months or as required...
Orange arrow How often does the APR-5000-XL need to be calibrated?

716 views
  It is recommended that the APR-5000-XL is calibrated every 12 months or as required. More calibration information can be found on the website....
Orange arrow Is there no heat from the Reflow (Top) Heater on the APR-5000-XL?

399 views
  Possible Causes: 1) The Reflow Heater is bad. 2) The RTD in the Reflow Heater is bad. 3) Bad solid state relay on the main PCBA. Possible Solution (corresponding to the Causes #): 1) Check the heater resistance. Replace heater head assembly (APR-HHA). Replacement instructions: APR-HHA Replace....
Orange arrow Is there an odd or strange plot for the Reflow Heater RTD on the APR-5000-XL?

382 views
  Possible Causes: 1) The RTD is out of possition. 2) There is a bad or intermittent RTD connection. Possible Solutions (corresponding to the Causes #): 1) Remove the heater head cover and reposition the RTD. APR-HHA Main RTD Position.pdf 2) Tighten the female connectors to the heater head RTD h...
Tagged: heating, heat, Heater, rtd, plot


Orange arrow Is there no or low Pre-Heater (bottom) heat on the APR-5000-XL?

652 views
  Possible Causes: 1) There is a bad connection. 2) Incorrect off-set setting in software. 3) No or low airflow through Pre-Heater. 4) Bad heater. 5) Bad solid state relay. Possible Solutions (corresponding to the Causes #): 1) Check connections to all heaters, both solid state relays, and the...
Orange arrow Is there a Pre-Heater RTD error on the APR-5000-XL?

660 views
  Possible Causes: 1) Bad connections or not plugged in. 2) Bad RTD. Possible Solutions (corresponding to the Causes #): 1) Check all connections to RTD's and to the PCB. 2) Replace the RTD assembly. Replacement instructions: APR-XL Preheater and RTD replacement.pdf If you need instructions on ...